VMware 2V0-16.25 Practice Test 36

Question 350

A hospital's vDS uplinks omit one tag and only VMs in a newly created ward VLAN fail. Suppose the team makes this shortcut instead: Choose an existing port group from another security zone because its VLAN is known to be working. Which outcome is the most likely direct consequence?

  1. Traffic becomes intermittent or a failover leads to asymmetric frame delivery
  2. The guest joins the wrong broadcast and security domain or has no intended service reachability
  3. Migration takes too long or fails, causing maintenance to miss approved windows
  4. Critical host services suffer packet loss or prolonged migration when competing network demand peaks

Answer & Explanations

Correct answer: B

A.

This failure concerns another scenario: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. In the stated case: A hospital's vDS uplinks omit one tag and only VMs in a newly created ward VLAN fail. The relevant consequence is: The guest joins the wrong broadcast and security domain or has no intended service reachability. The control that prevents it is: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks.

B.

The guest joins the wrong broadcast and security domain or has no intended service reachability. This is the risk in the stated situation: A hospital's vDS uplinks omit one tag and only VMs in a newly created ward VLAN fail. The risky shortcut is: Choose an existing port group from another security zone because its VLAN is known to be working. Prevent it by: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks.

C.

This failure concerns another scenario: A bank's management network remains healthy but host live migration repeatedly times out. In the stated case: A hospital's vDS uplinks omit one tag and only VMs in a newly created ward VLAN fail. The relevant consequence is: The guest joins the wrong broadcast and security domain or has no intended service reachability. The control that prevents it is: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks.

D.

This failure concerns another scenario: An education cluster's backup jobs saturate an uplink and slow critical host management traffic. In the stated case: A hospital's vDS uplinks omit one tag and only VMs in a newly created ward VLAN fail. The relevant consequence is: The guest joins the wrong broadcast and security domain or has no intended service reachability. The control that prevents it is: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks.

Question 351

An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Which VMware vSphere Foundation administration decision most directly addresses the described issue while keeping the change scoped?

  1. Configure supported distributed-switch port mirroring for an authorized, bounded VM or uplink capture session with protected destination
  2. Use a vSphere Distributed Switch for consistent multi-host policy where licensed and supported; keep standard switches for supported standalone needs
  3. Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring
  4. Configure VMkernel adapters for host-level management or migration services and VM port groups for guest interface connectivity

Answer & Explanations

Correct answer: C

A.

This action is appropriate in a different case: A network engineer needs to inspect one payment application's TCP retries without exposing other tenants. There, the reason is: Mirroring duplicates selected traffic to a collector without changing forwarding decisions, but unscoped monitoring can expose unrelated tenant information. The current case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The appropriate response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

B.

This action is appropriate in a different case: A hospital migrates VMs between two hosts whose independently created standard switch names differ. There, the reason is: A distributed switch centralizes port-group configuration across participating hosts, while each standard switch is administered per host. The current case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The appropriate response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

C.

Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. The technical reason is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding. The stated condition is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Confirm the result by: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

D.

This action is appropriate in a different case: A remote ESX host has guest traffic but no reachable management VMkernel interface. There, the reason is: A VMkernel NIC provides an ESX host service endpoint, whereas a VM port group attaches guest vNICs and cannot replace host management routing. The current case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The appropriate response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

Question 352

An insurer loses its VM network when the primary uplink fails because standby selection is wrong. An engineer recommends: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. Which technical explanation most directly justifies this recommendation?

  1. A distributed switch centralizes port-group configuration across participating hosts, while each standard switch is administered per host
  2. A VMkernel NIC provides an ESX host service endpoint, whereas a VM port group attaches guest vNICs and cannot replace host management routing
  3. Tagged frames must traverse each physical and virtual switching hop consistently; successful link status cannot establish that one VLAN is allowed
  4. Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding

Answer & Explanations

Correct answer: D

A.

This principle explains a different technical intervention: Use a vSphere Distributed Switch for consistent multi-host policy where licensed and supported; keep standard switches for supported standalone needs. It applies to: A hospital migrates VMs between two hosts whose independently created standard switch names differ. The actual case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The mechanism relevant here is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding.

B.

This principle explains a different technical intervention: Configure VMkernel adapters for host-level management or migration services and VM port groups for guest interface connectivity. It applies to: A remote ESX host has guest traffic but no reachable management VMkernel interface. The actual case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The mechanism relevant here is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding.

C.

This principle explains a different technical intervention: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks. It applies to: A manufacturing company adds a sensitive quality-control VLAN but the new port group uses the visitor tag. The actual case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The mechanism relevant here is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding.

D.

Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding. That mechanism explains the decision: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. In the reported situation: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Confirmation requires: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

Question 353

An insurer loses its VM network when the primary uplink fails because standby selection is wrong. After applying the relevant fix, which observable evidence would most convincingly establish that the underlying issue has been resolved?

  1. Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path
  2. Check host management or vMotion connectivity separately from VM guest network access after configuring the required adapter type
  3. Confirm address and gateway connectivity from a test VM attached to the new port group and inspect the physical allowed VLAN lists
  4. Complete a controlled VM migration and monitor the intended vMotion adapters and packet delivery at the planned MTU

Answer & Explanations

Correct answer: A

A.

Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path. This check directly tests: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. The underlying behavior is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding. The case is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong.

B.

This observation would verify a different remedy: Configure VMkernel adapters for host-level management or migration services and VM port groups for guest interface connectivity. That remedy applies to: A remote ESX host has guest traffic but no reachable management VMkernel interface. The present condition is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. To assess it, check: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

C.

This observation would verify a different remedy: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks. That remedy applies to: A manufacturing company adds a sensitive quality-control VLAN but the new port group uses the visitor tag. The present condition is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. To assess it, check: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

D.

This observation would verify a different remedy: Assign vMotion traffic to the designated VMkernel adapter with appropriate routing, VLAN and performance while preserving management access. That remedy applies to: A bank's management network remains healthy but host live migration repeatedly times out. The present condition is: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. To assess it, check: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

Question 354

An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Which apparently convenient shortcut would most directly undermine safe resolution of this specific situation?

  1. Choose an existing port group from another security zone because its VLAN is known to be working
  2. Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone
  3. Route bulk migration traffic across an unreviewed congested guest VLAN without checking isolation or throughput
  4. Reserve all uplink bandwidth for one low-priority class while expecting uninterrupted management and storage traffic

Answer & Explanations

Correct answer: B

A.

This proposed shortcut concerns a separate case: A manufacturing company adds a sensitive quality-control VLAN but the new port group uses the visitor tag. The risk in this question concerns: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Here the unsafe shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Use this response instead: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

B.

Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. This shortcut is unsafe for: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The resulting failure can be: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The safer response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

C.

This proposed shortcut concerns a separate case: A bank's management network remains healthy but host live migration repeatedly times out. The risk in this question concerns: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Here the unsafe shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Use this response instead: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

D.

This proposed shortcut concerns a separate case: An education cluster's backup jobs saturate an uplink and slow critical host management traffic. The risk in this question concerns: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Here the unsafe shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Use this response instead: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

Question 355

An insurer loses its VM network when the primary uplink fails because standby selection is wrong. Suppose the team makes this shortcut instead: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Which outcome is the most likely direct consequence?

  1. Migration takes too long or fails, causing maintenance to miss approved windows
  2. Critical host services suffer packet loss or prolonged migration when competing network demand peaks
  3. Traffic becomes intermittent or a failover leads to asymmetric frame delivery
  4. High-MTU vSAN or migration transfers fail intermittently despite apparent basic reachability

Answer & Explanations

Correct answer: C

A.

This failure concerns another scenario: A bank's management network remains healthy but host live migration repeatedly times out. In the stated case: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The relevant consequence is: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The control that prevents it is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

B.

This failure concerns another scenario: An education cluster's backup jobs saturate an uplink and slow critical host management traffic. In the stated case: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The relevant consequence is: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The control that prevents it is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

C.

Traffic becomes intermittent or a failover leads to asymmetric frame delivery. This is the risk in the stated situation: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The risky shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Prevent it by: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

D.

This failure concerns another scenario: A data center's vMotion uses a 9000-byte MTU but one upstream trunk accepts only standard frames. In the stated case: An insurer loses its VM network when the primary uplink fails because standby selection is wrong. The relevant consequence is: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The control that prevents it is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

Question 356

A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Which VMware vSphere Foundation administration decision most directly addresses the described issue while keeping the change scoped?

  1. Use a vSphere Distributed Switch for consistent multi-host policy where licensed and supported; keep standard switches for supported standalone needs
  2. Configure VMkernel adapters for host-level management or migration services and VM port groups for guest interface connectivity
  3. Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks
  4. Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring

Answer & Explanations

Correct answer: D

A.

This action is appropriate in a different case: A hospital migrates VMs between two hosts whose independently created standard switch names differ. There, the reason is: A distributed switch centralizes port-group configuration across participating hosts, while each standard switch is administered per host. The current case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The appropriate response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

B.

This action is appropriate in a different case: A remote ESX host has guest traffic but no reachable management VMkernel interface. There, the reason is: A VMkernel NIC provides an ESX host service endpoint, whereas a VM port group attaches guest vNICs and cannot replace host management routing. The current case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The appropriate response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

C.

This action is appropriate in a different case: A manufacturing company adds a sensitive quality-control VLAN but the new port group uses the visitor tag. There, the reason is: Tagged frames must traverse each physical and virtual switching hop consistently; successful link status cannot establish that one VLAN is allowed. The current case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The appropriate response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

D.

Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. The technical reason is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding. The stated condition is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Confirm the result by: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

Question 357

A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. An engineer recommends: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. Which technical explanation most directly justifies this recommendation?

  1. Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding
  2. A VMkernel NIC provides an ESX host service endpoint, whereas a VM port group attaches guest vNICs and cannot replace host management routing
  3. Tagged frames must traverse each physical and virtual switching hop consistently; successful link status cannot establish that one VLAN is allowed
  4. Live migration moves memory and runtime state over its host service network, and a working management link is not evidence of sufficient migration connectivity

Answer & Explanations

Correct answer: A

A.

Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding. That mechanism explains the decision: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. In the reported situation: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Confirmation requires: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

B.

This principle explains a different technical intervention: Configure VMkernel adapters for host-level management or migration services and VM port groups for guest interface connectivity. It applies to: A remote ESX host has guest traffic but no reachable management VMkernel interface. The actual case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The mechanism relevant here is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding.

C.

This principle explains a different technical intervention: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks. It applies to: A manufacturing company adds a sensitive quality-control VLAN but the new port group uses the visitor tag. The actual case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The mechanism relevant here is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding.

D.

This principle explains a different technical intervention: Assign vMotion traffic to the designated VMkernel adapter with appropriate routing, VLAN and performance while preserving management access. It applies to: A bank's management network remains healthy but host live migration repeatedly times out. The actual case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The mechanism relevant here is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding.

Question 358

A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. After applying the relevant fix, which observable evidence would most convincingly establish that the underlying issue has been resolved?

  1. Confirm address and gateway connectivity from a test VM attached to the new port group and inspect the physical allowed VLAN lists
  2. Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path
  3. Complete a controlled VM migration and monitor the intended vMotion adapters and packet delivery at the planned MTU
  4. Generate controlled competing traffic and confirm protected vMotion or storage classes maintain appropriate throughput without starving other services

Answer & Explanations

Correct answer: B

A.

This observation would verify a different remedy: Create the intended VLAN-backed distributed port group and permit the VLAN end-to-end on the physical uplinks. That remedy applies to: A manufacturing company adds a sensitive quality-control VLAN but the new port group uses the visitor tag. The present condition is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. To assess it, check: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

B.

Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path. This check directly tests: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring. The underlying behavior is: Teaming can offer redundancy or load distribution only when active and standby paths map correctly to physical forwarding. The case is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports.

C.

This observation would verify a different remedy: Assign vMotion traffic to the designated VMkernel adapter with appropriate routing, VLAN and performance while preserving management access. That remedy applies to: A bank's management network remains healthy but host live migration repeatedly times out. The present condition is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. To assess it, check: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

D.

This observation would verify a different remedy: Use supported Network I/O Control shares or reservations on eligible distributed switches to protect prioritized service traffic under contention. That remedy applies to: An education cluster's backup jobs saturate an uplink and slow critical host management traffic. The present condition is: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. To assess it, check: Disconnect one approved uplink in a controlled window and verify VM communication resumes through the expected alternate path.

Question 359

A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Which apparently convenient shortcut would most directly undermine safe resolution of this specific situation?

  1. Route bulk migration traffic across an unreviewed congested guest VLAN without checking isolation or throughput
  2. Reserve all uplink bandwidth for one low-priority class while expecting uninterrupted management and storage traffic
  3. Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone
  4. Enable jumbo frames only on ESX VMkernel interfaces and treat a normal ping as proof the full path supports them

Answer & Explanations

Correct answer: C

A.

This proposed shortcut concerns a separate case: A bank's management network remains healthy but host live migration repeatedly times out. The risk in this question concerns: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Here the unsafe shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Use this response instead: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

B.

This proposed shortcut concerns a separate case: An education cluster's backup jobs saturate an uplink and slow critical host management traffic. The risk in this question concerns: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Here the unsafe shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Use this response instead: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

C.

Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. This shortcut is unsafe for: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The resulting failure can be: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The safer response is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

D.

This proposed shortcut concerns a separate case: A data center's vMotion uses a 9000-byte MTU but one upstream trunk accepts only standard frames. The risk in this question concerns: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Here the unsafe shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Use this response instead: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

Question 360

A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. Suppose the team makes this shortcut instead: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Which outcome is the most likely direct consequence?

  1. Critical host services suffer packet loss or prolonged migration when competing network demand peaks
  2. High-MTU vSAN or migration transfers fail intermittently despite apparent basic reachability
  3. Sensitive workloads leak packet contents and the collector becomes a bottleneck
  4. Traffic becomes intermittent or a failover leads to asymmetric frame delivery

Answer & Explanations

Correct answer: D

A.

This failure concerns another scenario: An education cluster's backup jobs saturate an uplink and slow critical host management traffic. In the stated case: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The relevant consequence is: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The control that prevents it is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

B.

This failure concerns another scenario: A data center's vMotion uses a 9000-byte MTU but one upstream trunk accepts only standard frames. In the stated case: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The relevant consequence is: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The control that prevents it is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

C.

This failure concerns another scenario: A network engineer needs to inspect one payment application's TCP retries without exposing other tenants. In the stated case: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The relevant consequence is: Traffic becomes intermittent or a failover leads to asymmetric frame delivery. The control that prevents it is: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

D.

Traffic becomes intermittent or a failover leads to asymmetric frame delivery. This is the risk in the stated situation: A regional library adds a second uplink but activates LACP behavior on hosts without configuring matching switch ports. The risky shortcut is: Set both uplinks to a mode requiring a physical aggregate while leaving the switch ports standalone. Prevent it by: Configure supported NIC teaming and failover policies aligned with physical switch topology and effective link monitoring.

VMware vSphere Foundation 9.0 Administrator (2V0-16.25) Practice Tests