VMware 2V0-16.25 Practice Test 27

Question 260

A factory team adds a vSAN host but never configures the required VMkernel storage traffic service. Suppose the team makes this shortcut instead: Enable vSAN on three hosts that cannot reach one another over their vSAN traffic network. Which outcome is the most likely direct consequence?

  1. Disk groups cannot form or performance and rebuild behavior differ from the intended design
  2. Large storage frames fail intermittently and resync operations suffer loss or fragmentation
  3. Storage object creation or resynchronization fails because the requested placement is impossible
  4. Storage objects remain unavailable or unprotected because the distributed cluster cannot exchange data

Answer & Explanations

Correct answer: D

A.

This failure concerns another scenario: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. In the stated case: A factory team adds a vSAN host but never configures the required VMkernel storage traffic service. The relevant consequence is: Storage objects remain unavailable or unprotected because the distributed cluster cannot exchange data. The control that prevents it is: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing.

B.

This failure concerns another scenario: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. In the stated case: A factory team adds a vSAN host but never configures the required VMkernel storage traffic service. The relevant consequence is: Storage objects remain unavailable or unprotected because the distributed cluster cannot exchange data. The control that prevents it is: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing.

C.

This failure concerns another scenario: A medical archive requires redundant VM storage but its small cluster cannot meet an aggressive FTT policy. In the stated case: A factory team adds a vSAN host but never configures the required VMkernel storage traffic service. The relevant consequence is: Storage objects remain unavailable or unprotected because the distributed cluster cannot exchange data. The control that prevents it is: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing.

D.

Storage objects remain unavailable or unprotected because the distributed cluster cannot exchange data. This is the risk in the stated situation: A factory team adds a vSAN host but never configures the required VMkernel storage traffic service. The risky shortcut is: Enable vSAN on three hosts that cannot reach one another over their vSAN traffic network. Prevent it by: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing.

Question 261

A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Which VMware vSphere Foundation administration decision most directly addresses the described issue while keeping the change scoped?

  1. Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput
  2. Configure a supported NFS datastore with approved export, server address, NFS version and VMkernel network reachability
  3. Configure a supported storage multipathing policy and verify all expected active or standby paths to shared block storage
  4. Select VMware vSAN Express Storage Architecture only when the target hosts and disks meet its supported architecture and release prerequisites

Answer & Explanations

Correct answer: A

A.

Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. The technical reason is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links. The stated condition is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Confirm the result by: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

B.

This action is appropriate in a different case: A university ESX host can ping its NAS server but cannot mount the expected virtual machine export. There, the reason is: An NFS datastore requires compatible protocol access and authorized network/file permissions, distinct from block VMFS device formatting. The current case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The appropriate response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

C.

This action is appropriate in a different case: An insurer observes a single active SAN path despite having physically cabled two independent storage fabrics. There, the reason is: Multipath software selects usable storage routes and provides failover, but apparent link redundancy is meaningless when both paths share a failed device. The current case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The appropriate response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

D.

This action is appropriate in a different case: A data center has modern eligible flash hosts and wants ESA performance without introducing unsupported mixed devices. There, the reason is: ESA uses a distinct optimized storage stack with hardware eligibility requirements; it is not a universal switch that can be enabled on legacy OSA configurations. The current case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The appropriate response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

Question 262

A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. An engineer recommends: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. Which technical explanation most directly justifies this recommendation?

  1. Multipath software selects usable storage routes and provides failover, but apparent link redundancy is meaningless when both paths share a failed device
  2. vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links
  3. ESA uses a distinct optimized storage stack with hardware eligibility requirements; it is not a universal switch that can be enabled on legacy OSA configurations
  4. OSA uses disk-group organization with dedicated cache-tier behavior, unlike the ESA single-tier optimized device model

Answer & Explanations

Correct answer: B

A.

This principle explains a different technical intervention: Configure a supported storage multipathing policy and verify all expected active or standby paths to shared block storage. It applies to: An insurer observes a single active SAN path despite having physically cabled two independent storage fabrics. The actual case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The mechanism relevant here is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links.

B.

vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links. That mechanism explains the decision: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. In the reported situation: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Confirmation requires: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

C.

This principle explains a different technical intervention: Select VMware vSAN Express Storage Architecture only when the target hosts and disks meet its supported architecture and release prerequisites. It applies to: A data center has modern eligible flash hosts and wants ESA performance without introducing unsupported mixed devices. The actual case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The mechanism relevant here is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links.

D.

This principle explains a different technical intervention: Design vSAN Original Storage Architecture disk groups using supported cache and capacity devices with compatible controller modes. It applies to: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. The actual case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The mechanism relevant here is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links.

Question 263

A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. After applying the relevant fix, which observable evidence would most convincingly establish that the underlying issue has been resolved?

  1. Confirm hardware compatibility, ESA-capable disk and network requirements and healthy data services in a supported lab cluster
  2. Inspect disk-group health and cache/capacity role mapping after claiming storage devices in a test
  3. Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data
  4. Run vSAN health checks and prove node membership and interhost storage traffic before placing protected VMs

Answer & Explanations

Correct answer: C

A.

This observation would verify a different remedy: Select VMware vSAN Express Storage Architecture only when the target hosts and disks meet its supported architecture and release prerequisites. That remedy applies to: A data center has modern eligible flash hosts and wants ESA performance without introducing unsupported mixed devices. The present condition is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. To assess it, check: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

B.

This observation would verify a different remedy: Design vSAN Original Storage Architecture disk groups using supported cache and capacity devices with compatible controller modes. That remedy applies to: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. The present condition is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. To assess it, check: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

C.

Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data. This check directly tests: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. The underlying behavior is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links. The case is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames.

D.

This observation would verify a different remedy: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing. That remedy applies to: A regional retailer enables vSAN and reports missing object health because one host's storage VLAN is misconfigured. The present condition is: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. To assess it, check: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

Question 264

A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Which apparently convenient shortcut would most directly undermine safe resolution of this specific situation?

  1. Assign every device as capacity-only in OSA without validating the required cache role and controller compatibility
  2. Enable vSAN on three hosts that cannot reach one another over their vSAN traffic network
  3. Set every workload to the highest fault tolerance without checking whether the available host count can satisfy it
  4. Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size

Answer & Explanations

Correct answer: D

A.

This proposed shortcut concerns a separate case: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. The risk in this question concerns: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Here the unsafe shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Use this response instead: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

B.

This proposed shortcut concerns a separate case: A regional retailer enables vSAN and reports missing object health because one host's storage VLAN is misconfigured. The risk in this question concerns: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Here the unsafe shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Use this response instead: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

C.

This proposed shortcut concerns a separate case: A medical archive requires redundant VM storage but its small cluster cannot meet an aggressive FTT policy. The risk in this question concerns: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Here the unsafe shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Use this response instead: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

D.

Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. This shortcut is unsafe for: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The resulting failure can be: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The safer response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

Question 265

A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. Suppose the team makes this shortcut instead: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Which outcome is the most likely direct consequence?

  1. Large storage frames fail intermittently and resync operations suffer loss or fragmentation
  2. Storage objects remain unavailable or unprotected because the distributed cluster cannot exchange data
  3. Storage object creation or resynchronization fails because the requested placement is impossible
  4. The object remains noncompliant and required protection or storage efficiency is not achieved

Answer & Explanations

Correct answer: A

A.

Large storage frames fail intermittently and resync operations suffer loss or fragmentation. This is the risk in the stated situation: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The risky shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Prevent it by: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

B.

This failure concerns another scenario: A regional retailer enables vSAN and reports missing object health because one host's storage VLAN is misconfigured. In the stated case: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The relevant consequence is: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The control that prevents it is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

C.

This failure concerns another scenario: A medical archive requires redundant VM storage but its small cluster cannot meet an aggressive FTT policy. In the stated case: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The relevant consequence is: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The control that prevents it is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

D.

This failure concerns another scenario: A logistics operator wants RAID-5 capacity savings in a cluster with too few independent hosts. In the stated case: A hospital sees vSAN resync delays despite successful VM-to-VM pings because one uplink drops jumbo frames. The relevant consequence is: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The control that prevents it is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

Question 266

A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Which VMware vSphere Foundation administration decision most directly addresses the described issue while keeping the change scoped?

  1. Configure a supported storage multipathing policy and verify all expected active or standby paths to shared block storage
  2. Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput
  3. Select VMware vSAN Express Storage Architecture only when the target hosts and disks meet its supported architecture and release prerequisites
  4. Design vSAN Original Storage Architecture disk groups using supported cache and capacity devices with compatible controller modes

Answer & Explanations

Correct answer: B

A.

This action is appropriate in a different case: An insurer observes a single active SAN path despite having physically cabled two independent storage fabrics. There, the reason is: Multipath software selects usable storage routes and provides failover, but apparent link redundancy is meaningless when both paths share a failed device. The current case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The appropriate response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

B.

Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. The technical reason is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links. The stated condition is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Confirm the result by: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

C.

This action is appropriate in a different case: A data center has modern eligible flash hosts and wants ESA performance without introducing unsupported mixed devices. There, the reason is: ESA uses a distinct optimized storage stack with hardware eligibility requirements; it is not a universal switch that can be enabled on legacy OSA configurations. The current case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The appropriate response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

D.

This action is appropriate in a different case: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. There, the reason is: OSA uses disk-group organization with dedicated cache-tier behavior, unlike the ESA single-tier optimized device model. The current case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The appropriate response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

Question 267

A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. An engineer recommends: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. Which technical explanation most directly justifies this recommendation?

  1. ESA uses a distinct optimized storage stack with hardware eligibility requirements; it is not a universal switch that can be enabled on legacy OSA configurations
  2. OSA uses disk-group organization with dedicated cache-tier behavior, unlike the ESA single-tier optimized device model
  3. vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links
  4. A distributed datastore emerges from cooperating nodes; management reachability alone does not establish storage-network connectivity or consistent cluster membership

Answer & Explanations

Correct answer: C

A.

This principle explains a different technical intervention: Select VMware vSAN Express Storage Architecture only when the target hosts and disks meet its supported architecture and release prerequisites. It applies to: A data center has modern eligible flash hosts and wants ESA performance without introducing unsupported mixed devices. The actual case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The mechanism relevant here is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links.

B.

This principle explains a different technical intervention: Design vSAN Original Storage Architecture disk groups using supported cache and capacity devices with compatible controller modes. It applies to: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. The actual case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The mechanism relevant here is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links.

C.

vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links. That mechanism explains the decision: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. In the reported situation: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Confirmation requires: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

D.

This principle explains a different technical intervention: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing. It applies to: A regional retailer enables vSAN and reports missing object health because one host's storage VLAN is misconfigured. The actual case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The mechanism relevant here is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links.

Question 268

A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. After applying the relevant fix, which observable evidence would most convincingly establish that the underlying issue has been resolved?

  1. Inspect disk-group health and cache/capacity role mapping after claiming storage devices in a test
  2. Run vSAN health checks and prove node membership and interhost storage traffic before placing protected VMs
  3. Inspect policy compliance of representative VM storage objects and test an eligible host loss within the chosen protection level
  4. Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data

Answer & Explanations

Correct answer: D

A.

This observation would verify a different remedy: Design vSAN Original Storage Architecture disk groups using supported cache and capacity devices with compatible controller modes. That remedy applies to: A university upgrades an existing OSA cluster and confuses flash cache devices with the capacity tier. The present condition is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. To assess it, check: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

B.

This observation would verify a different remedy: Enable supported vSAN clustering only after validating compatible hosts, vSAN VMkernel traffic, storage devices and required licensing. That remedy applies to: A regional retailer enables vSAN and reports missing object health because one host's storage VLAN is misconfigured. The present condition is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. To assess it, check: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

C.

This observation would verify a different remedy: Assign supported vSAN storage policies with appropriate failures-to-tolerate, stripe and performance rules based on the workload and cluster capacity. That remedy applies to: A medical archive requires redundant VM storage but its small cluster cannot meet an aggressive FTT policy. The present condition is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. To assess it, check: Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data.

D.

Run vSAN network health and targeted VMkernel connectivity tests at the configured MTU before onboarding data. This check directly tests: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput. The underlying behavior is: vSAN uses interhost storage traffic independent of guest VM network status; a working guest port group does not prove vSAN kernel links. The case is: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk.

Question 269

A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Which apparently convenient shortcut would most directly undermine safe resolution of this specific situation?

  1. Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size
  2. Enable vSAN on three hosts that cannot reach one another over their vSAN traffic network
  3. Set every workload to the highest fault tolerance without checking whether the available host count can satisfy it
  4. Apply an erasure-coded policy to a topology with insufficient eligible fault domains

Answer & Explanations

Correct answer: A

A.

Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. This shortcut is unsafe for: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The resulting failure can be: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The safer response is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

B.

This proposed shortcut concerns a separate case: A regional retailer enables vSAN and reports missing object health because one host's storage VLAN is misconfigured. The risk in this question concerns: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Here the unsafe shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Use this response instead: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

C.

This proposed shortcut concerns a separate case: A medical archive requires redundant VM storage but its small cluster cannot meet an aggressive FTT policy. The risk in this question concerns: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Here the unsafe shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Use this response instead: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

D.

This proposed shortcut concerns a separate case: A logistics operator wants RAID-5 capacity savings in a cluster with too few independent hosts. The risk in this question concerns: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Here the unsafe shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Use this response instead: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

Question 270

A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. Suppose the team makes this shortcut instead: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Which outcome is the most likely direct consequence?

  1. Storage object creation or resynchronization fails because the requested placement is impossible
  2. Large storage frames fail intermittently and resync operations suffer loss or fragmentation
  3. The object remains noncompliant and required protection or storage efficiency is not achieved
  4. One rack outage removes too many replicas and leaves important virtual disks inaccessible

Answer & Explanations

Correct answer: B

A.

This failure concerns another scenario: A medical archive requires redundant VM storage but its small cluster cannot meet an aggressive FTT policy. In the stated case: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The relevant consequence is: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The control that prevents it is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

B.

Large storage frames fail intermittently and resync operations suffer loss or fragmentation. This is the risk in the stated situation: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The risky shortcut is: Set an oversized vSAN MTU on hosts while upstream switch ports remain at the default frame size. Prevent it by: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

C.

This failure concerns another scenario: A logistics operator wants RAID-5 capacity savings in a cluster with too few independent hosts. In the stated case: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The relevant consequence is: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The control that prevents it is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.

D.

This failure concerns another scenario: A hospital uses eight nodes across two racks but assumes every node belongs to a unique failure domain. In the stated case: A lab builds a dedicated vSAN VLAN that exists on hosts but not on one intervening switch trunk. The relevant consequence is: Large storage frames fail intermittently and resync operations suffer loss or fragmentation. The control that prevents it is: Create correctly routed or switched vSAN VMkernel adapters and verify end-to-end storage traffic MTU and throughput.