Question 960

A retail branch identifies a printer by MAC address but needs to locate the exact access port and assigned subnet. Which change and test should be carried out together before the issue is considered resolved?

  1. Compare FortiSwitch port speed, carrier, CRC/FCS errors, optical diagnostics and traffic rates to distinguish a physical problem from a valid yet blocked VLAN. Acceptance evidence: Swap one suspected cable or supported optic in staging, then confirm the targeted error counter stops increasing while client traffic continues.
  2. Compare actual FortiSwitchOS image version, target model and FortiGate FortiOS 7.6 support notes if a managed-switch configuration is repeatedly rejected or a switch reboots. Acceptance evidence: Apply a harmless test setting to a lab unit with matched releases and compare accepted versus rejected configuration details from the controller logs.
  3. When a switch loses central management, isolate the FortiLink transport or authorization cause first, preserving its known-good VLAN, tenant and access policies for recovery. Acceptance evidence: Confirm live local client forwarding and record the current controller and switch state, then restore only the management path and verify policy reconciliation.
  4. Inspect the FortiSwitch MAC address table, port VLAN membership and neighboring gateway ARP state before deciding whether a missing endpoint is mispatched or unroutable. Acceptance evidence: Move a permitted test host between access ports and verify its learned MAC appears in the expected VLAN and the correct gateway can be reached.

Explanation

Correct Answer

D:

The situation is that a retail branch identifies a printer by MAC address but needs to locate the exact access port and assigned subnet. Inspect the FortiSwitch MAC address table, port VLAN membership and neighboring gateway ARP state before deciding whether a missing endpoint is mispatched or unroutable. Acceptance evidence: Move a permitted test host between access ports and verify its learned MAC appears in the expected VLAN and the correct gateway can be reached. This pairing is justified because layer 2 learning identifies the port and VLAN where a source MAC was observed; an IP address without an associated VLAN/gateway path does not establish reachability.

Incorrect Answers

A:

This action and check address the distinct objective “Correlate switch interface counters with actual cable faults” instead of the stated acceptance requirement. The matching action is to inspect the FortiSwitch MAC address table, port VLAN membership and neighboring gateway ARP state before deciding whether a missing endpoint is mispatched or unroutable. Its confirming test is to move a permitted test host between access ports and verify its learned MAC appears in the expected VLAN and the correct gateway can be reached.

B:

The situation is that a retail branch identifies a printer by MAC address but needs to locate the exact access port and assigned subnet. This action and check address the distinct objective “Correlate FortiSwitch firmware compatibility with provisioning failures” instead of the stated acceptance requirement. The matching action is to inspect the FortiSwitch MAC address table, port VLAN membership and neighboring gateway ARP state before deciding whether a missing endpoint is mispatched or unroutable. Its confirming test is to move a permitted test host between access ports and verify its learned MAC appears in the expected VLAN and the correct gateway can be reached.

C:

This action and check address the distinct objective “Restore FortiLink connectivity without wiping tenant configuration” instead of the stated acceptance requirement. The matching action is to inspect the FortiSwitch MAC address table, port VLAN membership and neighboring gateway ARP state before deciding whether a missing endpoint is mispatched or unroutable. Its confirming test is to move a permitted test host between access ports and verify its learned MAC appears in the expected VLAN and the correct gateway can be reached.

Question 961

A regional hospital replaces a cabinet and discovers its managed FortiSwitch neighbor table no longer matches rack labels. What is the strongest initial engineering response to the described FortiSwitch 7.6 network scenario?

  1. Inspect the FortiSwitch MAC address table, port VLAN membership and neighboring gateway ARP state before deciding whether a missing endpoint is mispatched or unroutable.
  2. End the diagnostic capture, restrict the retained evidence, remove temporary SPAN or mirror destinations and verify normal switch traffic after the investigation.
  3. Compare FortiSwitch port speed, carrier, CRC/FCS errors, optical diagnostics and traffic rates to distinguish a physical problem from a valid yet blocked VLAN.
  4. Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration.

Explanation

Correct Answer

D:

Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. This resolves the issue because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves. To verify, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Incorrect Answers

A:

This option addresses the distinct objective “Interpret learned MAC locations and ARP entries for VLAN faults”, not the immediate requirement. Layer 2 learning identifies the port and VLAN where a source MAC was observed; an IP address without an associated VLAN/gateway path does not establish reachability. For the stated case, live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

B:

This option addresses the distinct objective “Remove capture artifacts and temporary mirror configuration after review”, not the immediate requirement. Troubleshooting instrumentation can remain a privileged copy of sensitive traffic long after it is useful; retaining it expands privacy and operational risk. For the stated case, live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

C:

This option addresses the distinct objective “Correlate switch interface counters with actual cable faults”, not the immediate requirement. Physical corruption changes frame integrity or link state, while an ACL or STP block can prevent forwarding without producing optical errors. For the stated case, live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Question 962

A regional hospital replaces a cabinet and discovers its managed FortiSwitch neighbor table no longer matches rack labels. What underlying forwarding, control-plane or operational behavior makes the correct solution work?

  1. Live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.
  2. Authentication, authorization and forwarding enforcement are separate stages; an accepted credential alone cannot prove that every intended ACL installed.
  3. A central policy may use a feature unsupported by the target device or image; deployment failure does not prove the FortiLink cable itself is defective.
  4. Control traffic cannot establish from a dark or mismatched link, and a reachable Ethernet peer can still fail discovery due to control configuration.

Explanation

Correct Answer

A:

Live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves. It supports this action: Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. To confirm, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Incorrect Answers

B:

That statement explains the distinct objective “Check port-access authentication and actual policy programming in tandem” rather than the cause in this case. The deciding mechanism here is that live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

C:

That statement explains the distinct objective “Correlate FortiSwitch firmware compatibility with provisioning failures” rather than the cause in this case. The deciding mechanism here is that live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

D:

That statement explains the distinct objective “Diagnose FortiLink physical layer and control VLAN separately” rather than the cause in this case. The deciding mechanism here is that live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Question 963

A regional hospital replaces a cabinet and discovers its managed FortiSwitch neighbor table no longer matches rack labels. What evidence should engineers collect before calling the relevant switching change successful?

  1. Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.
  2. Test a permitted and denied synthetic identity, compare controller policy with effective switch role, and confirm actual packet forwarding decisions.
  3. Run a controlled packet sequence at measured rates and confirm the analyzer receives it without missing frames while no ordinary device is connected to the mirror port.
  4. Audit the switch for active mirror sessions, verify intended production forwarding still works and store only the approved sanitized incident evidence.

Explanation

Correct Answer

A:

Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology. This is the relevant test because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Incorrect Answers

B:

This check would help evaluate the distinct objective “Check port-access authentication and actual policy programming in tandem”, but not the required result. For this case, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

C:

This check would help evaluate the distinct objective “Use an isolated mirror destination with sufficient bandwidth”, but not the required result. For this case, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

D:

This check would help evaluate the distinct objective “Remove capture artifacts and temporary mirror configuration after review”, but not the required result. For this case, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Question 964

A regional hospital replaces a cabinet and discovers its managed FortiSwitch neighbor table no longer matches rack labels. The unreviewed plan is: “Trust the label on a year-old patch-panel diagram while live LLDP shows the cable reaches a different managed switch.” What failure should the change owner expect?

  1. A technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.
  2. An inexpensive configuration mismatch remains unresolved while working physical links are disturbed by needless hardware changes.
  3. Large captures can exhaust diagnostic storage and expose unrelated private business traffic without advancing the specific incident.
  4. A valid loop-prevention control can be removed and turn an isolated access issue into a campus-wide broadcast storm.

Explanation

Correct Answer

A:

A technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved. The shortcut creates this risk because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Incorrect Answers

B:

That outcome concerns the distinct objective “Trace LACP negotiations during a suspected aggregate fault”; it is not the most direct consequence of this shortcut. The relevant consequence is that a technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.

C:

That outcome concerns the distinct objective “Capture FortiSwitch interface traffic with narrow filters”; it is not the most direct consequence of this shortcut. The relevant consequence is that a technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.

D:

That outcome concerns the distinct objective “Read STP state and topology counters alongside performance symptoms”; it is not the most direct consequence of this shortcut. The relevant consequence is that a technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.

Question 965

A regional hospital replaces a cabinet and discovers its managed FortiSwitch neighbor table no longer matches rack labels. Which change and test should be carried out together before the issue is considered resolved?

  1. Inspect FortiGate FortiLink interface state, transceiver compatibility, aggregate members, IP addressing and neighbor detection before changing managed-switch VLAN profiles. Acceptance evidence: Compare link carrier and optical errors with FortiGate discovery logs, then change only the proven faulty port or control parameter and observe switch registration.
  2. Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Acceptance evidence: Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.
  3. Configure a supported FortiSwitch traffic mirror to a dedicated monitored analyzer port, estimating aggregate source load and restricting access to recorded frames. Acceptance evidence: Run a controlled packet sequence at measured rates and confirm the analyzer receives it without missing frames while no ordinary device is connected to the mirror port.
  4. Compare FortiSwitch port speed, carrier, CRC/FCS errors, optical diagnostics and traffic rates to distinguish a physical problem from a valid yet blocked VLAN. Acceptance evidence: Swap one suspected cable or supported optic in staging, then confirm the targeted error counter stops increasing while client traffic continues.

Explanation

Correct Answer

B:

Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Acceptance evidence: Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology. This pairing is justified because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Incorrect Answers

A:

This action and check address the distinct objective “Diagnose FortiLink physical layer and control VLAN separately” instead of the stated acceptance requirement. The matching action is to compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Its confirming test is to trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

C:

This action and check address the distinct objective “Use an isolated mirror destination with sufficient bandwidth” instead of the stated acceptance requirement. The matching action is to compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Its confirming test is to trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

D:

This action and check address the distinct objective “Correlate switch interface counters with actual cable faults” instead of the stated acceptance requirement. The matching action is to compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Its confirming test is to trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Question 966

A logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Which switching configuration or operational decision best addresses the stated requirement without weakening unrelated controls?

  1. Correlate FortiSwitch 802.1X or MAC-auth session state, RADIUS response, effective port VLAN/role and policy counters before opening a denied endpoint.
  2. Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration.
  3. End the diagnostic capture, restrict the retained evidence, remove temporary SPAN or mirror destinations and verify normal switch traffic after the investigation.
  4. Compare FortiSwitch port speed, carrier, CRC/FCS errors, optical diagnostics and traffic rates to distinguish a physical problem from a valid yet blocked VLAN.

Explanation

Correct Answer

B:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. This resolves the issue because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves. To verify, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Incorrect Answers

A:

This option addresses the distinct objective “Check port-access authentication and actual policy programming in tandem”, not the immediate requirement. Authentication, authorization and forwarding enforcement are separate stages; an accepted credential alone cannot prove that every intended ACL installed. For the stated case, live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

C:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. This option addresses the distinct objective “Remove capture artifacts and temporary mirror configuration after review”, not the immediate requirement. Troubleshooting instrumentation can remain a privileged copy of sensitive traffic long after it is useful; retaining it expands privacy and operational risk. For the stated case, live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

D:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. This option addresses the distinct objective “Correlate switch interface counters with actual cable faults”, not the immediate requirement. Physical corruption changes frame integrity or link state, while an ACL or STP block can prevent forwarding without producing optical errors. For the stated case, live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Question 967

A logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Which networking principle best explains why the appropriate approach would solve this problem?

  1. A TCP retransmission can reflect several causes; only matching timestamps, path direction and hardware errors can locate the actual loss boundary.
  2. FortiOS 7.6 releases can differ in FortiLink neighbor-detection defaults; a valid physical link does not guarantee the current discovery protocol is enabled.
  3. Physical corruption changes frame integrity or link state, while an ACL or STP block can prevent forwarding without producing optical errors.
  4. Live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Explanation

Correct Answer

D:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves. It supports this action: Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. To confirm, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Incorrect Answers

A:

That statement explains the distinct objective “Use packet timestamps to separate retransmission from switch drops” rather than the cause in this case. The deciding mechanism here is that live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

B:

That statement explains the distinct objective “Check FortiLink LLDP discovery after FortiOS minor version changes” rather than the cause in this case. The deciding mechanism here is that live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

C:

That statement explains the distinct objective “Correlate switch interface counters with actual cable faults” rather than the cause in this case. The deciding mechanism here is that live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Question 968

A logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Which controlled diagnostic or acceptance observation would best prove this solution has worked?

  1. Confirm live local client forwarding and record the current controller and switch state, then restore only the management path and verify policy reconciliation.
  2. Test a permitted and denied synthetic identity, compare controller policy with effective switch role, and confirm actual packet forwarding decisions.
  3. Inspect the configured FortiLink neighbor-detect method and compare observed LLDP frames and managed-switch discovery before and after a lab reconnect.
  4. Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Explanation

Correct Answer

D:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology. This is the relevant test because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Incorrect Answers

A:

This check would help evaluate the distinct objective “Restore FortiLink connectivity without wiping tenant configuration”, but not the required result. For this case, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

B:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. This check would help evaluate the distinct objective “Check port-access authentication and actual policy programming in tandem”, but not the required result. For this case, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

C:

This check would help evaluate the distinct objective “Check FortiLink LLDP discovery after FortiOS minor version changes”, but not the required result. For this case, trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

Question 969

A logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. An engineer suggests “Trust the label on a year-old patch-panel diagram while live LLDP shows the cable reaches a different managed switch.” What is the most likely adverse network outcome?

  1. A technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.
  2. The relevant discovery or provisioning failure remains hidden while unrelated application traffic dominates collected evidence.
  3. The switch remains undiscovered even though cabling, port speed and interface IP settings appear correct.
  4. A valid loop-prevention control can be removed and turn an isolated access issue into a campus-wide broadcast storm.

Explanation

Correct Answer

A:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. A technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved. The shortcut creates this risk because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Incorrect Answers

B:

That outcome concerns the distinct objective “Select capture filters that isolate FortiLink discovery and control”; it is not the most direct consequence of this shortcut. The relevant consequence is that a technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.

C:

That outcome concerns the distinct objective “Check FortiLink LLDP discovery after FortiOS minor version changes”; it is not the most direct consequence of this shortcut. The relevant consequence is that a technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.

D:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. That outcome concerns the distinct objective “Read STP state and topology counters alongside performance symptoms”; it is not the most direct consequence of this shortcut. The relevant consequence is that a technician can disconnect the wrong FortiLink or ISL, creating a new management outage while the original fault remains unresolved.

Question 970

A logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. What implementation and acceptance-evidence pair best addresses the network requirement?

  1. Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Acceptance evidence: Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.
  2. On the relevant 7.6 maintenance release, verify whether FortiLink neighbor detection uses LLDP or another supported method and that the interface has required LLDP reception and transmission. Acceptance evidence: Inspect the configured FortiLink neighbor-detect method and compare observed LLDP frames and managed-switch discovery before and after a lab reconnect.
  3. Observe the correct LACP control exchanges and partner identities on intended aggregate member interfaces while comparing them to switch operational LAG state. Acceptance evidence: Disable one lab LAG member and check whether the partner state and active member set update as expected without breaking traffic.
  4. Compare FortiSwitch port speed, carrier, CRC/FCS errors, optical diagnostics and traffic rates to distinguish a physical problem from a valid yet blocked VLAN. Acceptance evidence: Swap one suspected cable or supported optic in staging, then confirm the targeted error counter stops increasing while client traffic continues.

Explanation

Correct Answer

A:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. Compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Acceptance evidence: Trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology. This pairing is justified because live link-neighbor discovery exposes observed device attachment while diagrams show intended paths; a mismatch can reveal incorrect port or cable moves.

Incorrect Answers

B:

This action and check address the distinct objective “Check FortiLink LLDP discovery after FortiOS minor version changes” instead of the stated acceptance requirement. The matching action is to compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Its confirming test is to trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

C:

This action and check address the distinct objective “Trace LACP negotiations during a suspected aggregate fault” instead of the stated acceptance requirement. The matching action is to compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Its confirming test is to trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.

D:

The situation is that a logistics depot moves fiber between closets and must identify a duplicated inter-switch connection before a controller change. This action and check address the distinct objective “Correlate switch interface counters with actual cable faults” instead of the stated acceptance requirement. The matching action is to compare FortiSwitch LLDP remote chassis and port IDs with approved ISL, FortiLink and edge assignments before repatching cables or changing stack configuration. Its confirming test is to trace both ends of a synthetic link by LLDP and port status and verify that a documented patch correction restores the intended managed topology.